| Search our site Loading
|
![]() |
Questions ? Call us at 905-624-5536 |
||
|
| Heidenhain TL Nano Laser tool measurement system Specs |
![]() |
| Heidenhain TL Micro 150 laser tool measurement system Specs |
![]() |
| Heidenhain TL Micro 200 tool measurement system Specs |
![]() tool diameter measurement system |
| Heidenhain TL Micro 300 Laser tool measurement system Specs |
![]() tool length measurement system |
| Workpiece measurement with the TL laser
system offers special benefits for workpiece measurement. The contact-free measuring method by laser beam enables you to check even the smallest tools rapidly, reliably and without collision. And modern cutting materials of hard, brittle materials are no problem for the TL laser systems. Because the tool is measured at rated speed, errors on the tool, spindle and holder are detected and corrected directly. |
|
| Specifications | TL Nano |
TL Micro 150 |
TL Micro 200 |
TL Micro 300 |
| Tool diameter Central measurement Tangential measurement from above Tangential measurement from the side |
0.03 to 37 mm 0.03 to 44 mm 0.03 to 44 mm |
0.03 to 30 mm 0.03 to 30 mm 0.03 to 30 mm |
0.1 to 80 mm 0.1 to 98 mm 0.1 to 122 mm |
0.1 to 180 mm 0.1 to 324 mm 0.1 to 428 mm |
| Repeatability | ± 0.2 µm |
± 1 µm |
||
| Spindle speed* | For individual tooth measurement, optimized to standard spindles or HSC spindles (> 30 000 min-1) |
|||
| Laser Wavelength / Power Protection class IEC 825 |
Visible red-light laser with beam focused at center of system
630 to 700 nm / < 1 mW 2 |
|||
| Input signals | Square-wave signals 24 V – • ENABLE 0 transmission enabling • ENABLE 1 receiver enabling 1 • ENABLE 2 receiver enabling 2 |
|||
| Output signals | Square-wave signals 24 V – • DYN dynamic triggering signal • STA static triggering signal • LASER OK |
|||
| Power supply | 24 V / 160 mA |
|||
| Electrical connection | M23 flange socket, male, 12-pin |
|||
| Cable outlet* | On the side
|
On the side or bottom |
||
| Mounting | Within the machine work envelope |
|||
| Protection IEC 60 529 | IP 68 (when connected, with sealing air) |
|||
| Tool cleansing | Integral blowing unit |
|||
| Operating temperature Storage temperature |
10 to 40 °C 0 to 50 °C |
|||
| Weight (approx.) | Incl. blowing unit |
|||
| Cable outlet on side | 0.70 kg |
0.85 kg |
0.95 kg |
1.15 kg |
| Cable outlet on bottom | - |
0.90 kg |
1.00 kg |
1.20 kg |