TS Series:     Workpiece probing systems


Measuring workpieces
The stylus of a TS three-dimensional touch trigger probe is deflected upon contact with a workpiece surface. This releases a trigger signal in the TS that is transmitted to the control either through a cable (TS 220 and TS 230) or as an infrared light signal (TS 7xx, TS 6xx, TS 4xx). The control simultaneously saves the actual position values as measured by the machine axis encoders, and uses this information for further processing.
Click on the numbers on the top right to adjust the speed.
Click on the symbols at lower left to start, stop and repeat.

Download the complete Heidenhain Probe catalogue in .pdf format

Link to Heidenhain Laser tool probes
Link to Heidenhain tool touch probes
Specifications and Dimensions for TS 220 Heidenhain TS-220 touch probe
Area of application Workpiece touch probe
Type of transmission Cable
Probe accuracy ≤ ± 5 µm when using a standard stylus
Probe repeatability (repeated probing from one direction) 2σ ≤ 1 µm at a probing velocity of 1 m/min
Max. deflection of probe contact 5 mm in all directions
Deflection forces Axial: approx. 0,2 N
Radial: approx. 0,6 N
Probe velocity Max. 5 m/min
Protection IEC 60529 IP 55
Operating temperature 10°C to 40 °C
Storage temperature - 20°C to 70 °C
Weight Approx . 0.7 kg without taper shank
Clamping shaft With taper shank
Without taper shank (connecting thread M30 x 0.5)
Power supply 5 V ± 5 %
Electrical connection Spiral cable 1.5 m with 6-pin quick disconnect
Current consumption (w/o load) ≤ 100 mA
Input/output signals One square-wave signal and its inverted signal
Trigger signal S
Signal level: TTL
UH ≥ 2.5 V at IH ≤ 20 mA
UL ≤ 0.5 V at IL ≤ 20 mA
at 5 V rated voltage
   
Accessories SE 540 and SE 640

* Please indicate when ordering
1) Via adaptor, included in delivery
2) Included in delivery


Specifications and Dimensions for TS 440, TS 444
Specifications TS 440 - Battery Powered TS 444 - Air turbine generator
Probe accuracy ≤ ± 5 µm when using a standard stylus
Probe repeatability
Repeated probing from one direction
2 σ ≤ 1 µm at a probing velocity of 1 m/min
Typical values:
2 σ ≤ 1 µm at a probing velocity of 3 m/min
2 σ ≤ 4 µm at a probing velocity of 5 m/min
Deflection of probe contact ≤ 5 mm in all directions (with stylus length L = 40 mm)
Deflection force Axial: approx. 7 N / Radial: approx. 0.7 to 1.3 N
Probe velocity ≤ 5 m/min
Protection IEC 60529 IP 67
Operating temperature / Storage temperature 10 °C to 40 °C / –20 °C to 70 °C
Weight without taper shank Approx. 0.4 kg
Taper shank*
  With taper shank (for selection see Touch Probes brochure)
  Without taper shank (connecting thread M12 x 0.5)
Signal transmission Infrared transmission with 360° range
Transmission angle of infrared signal* 0° or +30°
Transmitter/receiver unit* SE 540 or SE 640
TS switch-on/off Infrared signal from SE
Power supply
Batteries, rechargeable or non-rechargeable Recommended operating pressure of the compressed air (5.5 to 8) x 105 Pa
Power storage
2 batteries (rechargeable or non-rechargeable), size 2/3 AA or Size N1) each 1 to 4 V Integrated high-power capacitors; typ. 3 sec. at 5.5 x 105 Pa
Operating time Continuous duty typically 200 hours with lithium batteries2) 3.6 V/1200 mAh Typ. 120 s
Accessories SE 540 and SE 640

* Please indicate when ordering
1) Via adaptor, included in delivery
2) Included in delivery


Specifications and Dimensions for TS 640, TS 740
Specifications TS 640 TS 740
Probe accuracy ≤ ± 5 µm when using a standard stylus ≤ ± 1 µm when using a standard stylus
Probe repeatability
Repeated probing from one direction
2 σ ≤ 1 µm at a probing velocity of 1 m/min
Typical values:
2 σ ≤ 1 µm at a probing velocity of 3 m/min
2 σ ≤ 4 µm at a probing velocity of 5 m/min
2 σ ≤ 0.25 µm at a probing velocity of 0.25 m/min
Deflection of probe contact ≤ 5 mm in all directions (with stylus length L = 40 mm)
Deflection force Axial: approx. 8 N / Radial: approx. 1 N Axial: approx. 0.6 N / Radial: approx. 0.2 N
Probe velocity ≤ 5 m/min ≤ 0.25 m/min
Protection IEC 60529 IP 67
Operating temperature / Storage temperature 10°C to 40 °C  /  –20°C to 70°C
Weight without taper shank Approx. 1.1 kg
Taper shank*
     With taper shank (for selection see Touch Probes brochure)
   Without taper shank (connecting thread M30 x 0.5)
Signal transmission Infrared transmission with 360° range
Transmission angle of infrared signal* 0° or +30°
Transmitter/receiver unit* SE 540 or SE 640
TS switch-on/off Infrared signal from SE
Power supply 2 batteries (rechargeable or non-rechargeable), size C, 1 V to 4 V each
Operating time1) Continuous duty approx. 800 h Continuous duty approx. 100 h
Accessories SE 540 and SE 640
APE 642 Interface Electronics

* Please indicate when ordering
1) With lithium batteries 3.6 V/6000 mAh (included in delivery)